Inspecting the Condensation Box

Some locations may choose to do this procedure on a more frequent basis (i.e., quarterly, semi-annually, or other frequency).

To avoid electrical shock or property damage, move the power switch to OFF and disconnect power.

Inspect that the condensation box and condensation drain line are clean, and free from debris. Use a flexible wire brush to remove debris from the condensation drain line.

  1. Remove rear cover of fryer.

  2. Disconnect deadweight tube (1).

  3. Disconnect steam exhaust hose (2).

  4. Disconnect condensation drain line (3).

  5. Disconnect plumbing from pressure solenoid outlet (4).

  6. Remove condensation box mounting screws.

  7. Cut silicone.

  8. Remove the four screws fastening the lid to the box (5) and remove lid.

  9. Remove any debris from the inside of the condensation box and clean.

  10. Remove any debris in the condensation drain line and in the condensation drain outlet (6).

  11. Seal lid to box with silicone.

  12. Reassemble in reverse order.