Inspecting the Temperature Probe
Some locations may choose to do this procedure on a more frequent basis (i.e., quarterly, semi-annually, or other frequency).
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
Inspect temperature probe, verify it is not bent or damaged. Check the insertion depth of the probe with a gauge – adjust if necessary.
-
Remove electrical power supplied to the fryer.
-
Drain the oil from the vat.
-
Remove the control panel.
-
Ensure the temperature probe fits into the compression fitting until it extends one-half (1/2) inch (1.3 cm) into the vat.
-
Use the temperature probe gauge, to ensure proper placement in vat.
Excess force will damage the temperature probe.
-
Replace control panel.
-
Replace oil in vats.
-
Turn power on and test fryer.