Stats Mode

Press and hold the PROG button until "L-2 LEVEL 2", followed by, "CLOCK SET", shows in display.

Press the PROG button 4 times and "STATS", followed by, "ENTER CODE" shows in display.

Enter code 11221122 to access the following items: (Use hidden buttons, see Components.)

ST-1 Power live hours

ST-2 Power "on' hours

ST-3 Power-ups count

ST-4 Errors count

ST-5 Air heat "on' hours

ST-6 Water heater "on' hours

ST-7 Circulation fan "on' hours

ST-8 Water solenoid on hours

ST-9 Solenoid cycle count

ST-10 Longest solenoid on time; max.=5 minutes

ST-11 Vent motor

ST-12 Highest air temperature

ST-13 Highest water heater temperature

ST-14 Factory Use

ST-15 Highest humidity value

ST-16 Highest CPU temperature

ST-17 Water heater (too hot) cycle count

ST-18 Sys ram - fade count

ST-19 Hold ram - fade count

ST-20 Stat ram - fade count

ST-21 Ram data error count

ST-22 Data total loss count

ST-23 User init's count

ST-24 Auto init's count

ST-25 Error log

ST-26 Power-up log

ST-27 Factory Use

ST-28 Reset all stats

The PROG button moves you forward through the above selections and the INFO button moves you backwards through the selections.

Function Description

ST-1: Power Live Hours

This section shows the number of hours the control has been on.

ST-2: Power On Hours

This section shows the number of hours the control has been on.

ST-3: Power Ups Count

This section shows the number of times the control has been turned on.

ST-4: Errors Count

This section shows the total number of all errors (displayed on control) that have occurred with the unit.

ST-5: Air Heat On Hours

This section shows the number of hours the air heaters have been on.

ST-6: Water Heater On Hours

This section shows the number of hours the water heater has been on.

ST-7: Circulation Fan On Hours This section shows the number of hours the cooling fan has been on.
ST-8: Water Solenoid On Hours

Shows the number of hours the solenoid has been on.

ST-9: Solenoid Cycle Count

Shows the number of times the solenoid has been turned on.

ST-10: Longest Solenoid "On' time. Maximum 5 minutes.

Shows the longest the solenoid has been on at any one time, to a maximum of 5 minutes.

ST-11: Vent Motor On Hours

This section shows the number of hours the vent motor has been on.

ST-12: Highest Air Temperature

This section shows highest air temperature sensed by the temperature probe.

ST-13: Highest Water Heater Temperature This section shows the highest water heater temperature, sensed by the water heater temperature sensor.
ST-14: Highest Food Temperature

Factory use.

ST-15: Highest Humidity Value

This section shows the highest humidity value sensed by the humidity sensor.

ST-16: Highest CPU Temperature

This section shows the highest control board temperature sensed by the control.

ST-17: Water heater (too hot) cycle count

Shows the number of times the water heater has gotten too hot.

ST-18: System Ram - Fade Count

This section shows the number of times the system memory has been lost during power up. Ex: °F or °C, or speaker volume.

ST-19: Hold Ram - Fade Count

This section shows the number of times the hold memory has been lost during a power up. May be lost at a power up, after a power loss, during a holding cycle.

ST-20: Stat Ram - Fade Count

This section shows the number of times the stats memory has been lost during power up. The information in the Stats Mode is updated every two hours, and this count lets you know that the updates were lost.

ST-21: Ram Data Error Count

This section shows the number of times the data was lost while operating, not during power up. (Should be a low number.)

ST-22: Data Total Loss Count

This section shows the number of times the data stored in the Eprom has been lost. Should see an "E-41" error code when this occurs.

ST-23: User Init's Count

This section shows the number of times the operator has initialized the controls.

ST-24: Auto Init's Count

This section shows the number of times the controls have initialized itself.

ST-25: Error Log

This section records the last 10 errors and the time they occurred. Press the Down arrow button and Up arrow button to view the log.

ST-26: Power Up Log

This section records the last 10 power ups and when they oc- curred. Press the Down arrow button and Up arrow button to view the log.

ST-27: Heat Up Log This section records the last 10 heat ups between 250° F (121° C) to 300° F (149° C), when they occurred, and how long (seconds) it took. Press the Down arrow button and Up arrow button to view the log.
ST-28: Resets All Stats

This section allows the user to reset all data stored in the Stats Mode. Press and hold the Down arrow button for 3 seconds.

The Data Logging and Manufacturing Mode are mainly for Henny Penny use only. For more information on these modes, contact the Service Department at +1-800-417-8405 or +1-937-456-8405.