Stats Mode
This mode allows a technician to view advanced information on the operation of the fryer and controls.
-
Press and hold the program button for 5 seconds until “LEVEL 2”, followed by, “SP PROG” and “ENTER CODE” show in the display.
-
Press the program button 5 times and “STATS” and “ENTER CODE” flash in the left display.
-
Enter code 1, 1, 2, 2, 1, 1, 2, 2 (first 2 product buttons).
-
“ST-1 STATS LAST RESET ON...” flashes in the left display and the date shows in the right display. Use the up and down arrow buttons to select the steps.
If a bad code is entered, a tone sounds and “BAD CODE” shows on the display. Wait a few seconds, the controls revert back to the cook mode, and repeat the above steps.
Press and hold the program button at anytime to return to normal operation.
Program Code | Description |
---|---|
ST-1 | Stats Last Reset Date |
ST-2 | Fryer Total Running Hours |
ST-3 | Left Vat Melt Cycle Hours |
ST-4 | Left Vat Cook Cycle Hours |
ST-5 | Left Vat Idle Hours |
ST-6 | Right Vat Melt Cycle Hours |
ST-7 | Right Vat Cook Cycle Hours |
ST-8 | Right Vat Idle Hours |
ST-9 | Power-Ups Count |
ST-10 | Error Counts |
ST-11 |
Left Vat Heat On Hours |
ST-12 | Right Vat Heat On Hours |
ST-13 | Highest Left Vat Oil Temperature |
ST-14 | Highest Right Vat Oil Temperature |
ST-15 | Highest CPU Temperature |
ST-16 |
System RAM Fade Count |
ST-17 | Cook RAM Fade Count |
ST-18 | Product RAM Fade Count |
ST-19 | Stat RAM Fade Count |
ST-20 | RAM Data Error Count |
ST-21 |
Data Total Loss Count |
ST-22 | User Initialization Count |
ST-23 | Automatic Initialization Count |
ST-24 | Cooks Count per Product |
ST-25 | Cook Cycle Stop Counts |
ST-25A |
Number Of Stops In First 30 Seconds |
ST-25B | 0 |
ST-25C | 0 |
ST-25D | Complete Cook Cycles Counted |
ST-26 | Reset All Stats |