Applies to:
Replacing Filter Pump Seal Kit - Gerotor
-
Flat Tip Screwdriver or Prying Tools and supplies
-
1/2" (13 mm) Wrench or Socket
-
3/4" (19 mm) Socket
-
Hammer
-
Basic Hand Tools
-
Gasket
-
Shaft Seal
-
Cap O-ring
-
Cap Bolts
Estimated Time
30 minutes
|
Only perform this procedure when the unit is cool or severe burns may result. |
|
This appliance contains no user serviceable parts - servicing shall be carried out only by authorized personnel. For spare parts and service contact the manufacturer or authorized local agent for this product. To avoid electrical shock or property damage, disconnect power before installing or servicing equipment. |
Follow these steps to replace the seal kit for gerotor pump.
Preparing Fryer
-
Turn power switch off.
-
Ensure fryer is cool to the touch before moving.
-
Pull out the fryer and unplug from power source.
Removing Old Seal Kit
-
Using flat tip screwdriver or prying tool, remove gasket from pump.
-
Using a 1/2" (13 mm) wrench or socket, remove 4 bolts securing pump cap.
-
Remove shaft rotor.
-
Remove outer gear.
-
Using flat tip screwdriver or prying tool, remove cap o-ring.
-
Using flat tip screwdriver or prying tool, remove shaft seal.
NOTE: Thoroughly clean all parts with degreaser before reassembly.
Installing New Seal Kit
|
|
-
Locate new shaft seal from kit. Place seal into place and using 3/4" (19 mm) socket, hammer into position.
-
Locate new cap o-ring from kit. Lubricate o-ring with food safe oil and install into cap.
-
Reinstall shaft rotor and outer gear.
-
Reinstall cap making sure narrow slots are pointing up.
-
Locate new gasket from kit and install on pump.
-
Reinstall pump onto motor using 1/2" (13 mm) wrench or socket to tighten bolts.
|
|
NOTE: Cap can only be installed in one direction, bolt holes will not line up correctly if installed in wrong direction.
NOTE: Lubricate motor shaft before installing pump.