Inspecting the Condensation Box and Component

Some locations may choose to do this procedure on a more frequent basis (i.e., quarterly, semi-annually, or other frequency).

To avoid personal injury, do not remove any condensation box components while fryer is in use.

Only perform this procedure when the fryer is cool and disconnected from the power source.

Ensure the condensation box and related components are undamaged and working within specification by doing the following:

  1. If necessary, remove the steam exhaust by loosening the thumb screws.

  2. Clean steam exhaust, deadweight and gasket in warm soapy water as necessary.

  3. Close and lock the lid.

  4. Using a crosshead screwdriver, remove the lids top cover.

  5. Using a crosshead screwdriver, remove the service access panel behind the lid.

  6. Using a crosshead screwdriver, remove the condensation box lid.

  7. Clean the box, lid and gaskets as necessary.

  8. Replace gaskets and other components as necessary.

  9. Continue to the next inspection or reinstall components as applicable.