Applies to:
Specifications
Review the information below to become familiar with the appliance operation.
|
Pressure |
|
|---|---|
|
Operating pressure |
12.0 psi (82.7 kPa) |
|
Safety valve setting |
14.5 psi (100.0 kPa) |
|
Heating |
|
|---|---|
|
2 immersed elements, each with three heaters. |
8500 watts |
| Capacity | |
|---|---|
|
Product |
24 lbs. (10.9 kg) 8 heads of chicken |
|
Fry VAT Oil |
75 lbs. (34 liters) |
|
Oil Reservoir |
15 lbs. (6.8 liters) |
| Vat Dimensions | |
|---|---|
| Side to side | 15 inches |
| Front to rear | 20.5 inches |
| Top to bottom | 17 inches |
Ensure the appliance is installed with the required clearance.
|
Dimensions |
||
|
Height |
62.00 in. |
(1585 mm) to top of stack |
|
Height |
73.00 in. |
(1859 mm) lid up to clean |
|
Width |
24.00 in. |
(610 mm) |
|
Depth |
41.00 in. |
(1030 mm) |
|
Clearance |
||
|
Top |
6 in. |
(152 mm) lid up to clean |
|
Sides |
6 in. |
(152 mm) air flow |
|
Back |
6 in. |
(152 mm) air flow |
|
Front |
38 in. |
(965 mm) remove drain pan |
|
Dimensions |
||
|
Height |
57.00 in. |
(1454 mm) to top of stack |
|
Height |
74.00 in. |
(1819 mm) lid up to clean |
|
Width |
24.00 in. |
(610 mm) |
|
Depth |
41.00 in. |
(1030 mm) |
|
Clearance |
||
|
Top |
6 in. |
(152 mm) lid up to clean |
|
Sides |
6 in. |
(152 mm) air flow |
|
Back |
6 in. |
(152 mm) air flow |
|
Front |
38 in. |
(965 mm) remove drain pan |
Data Plate Location
In addition, the serial number is stamped on the outside of the counter top.
Related Content
Installing the PXE 100 Pressure Fryer
Operating the PXE 100 Pressure Fryer
Programming the PXE 100 Pressure Fryer
Troubleshooting the PXE 100 Pressure Fryer
Reference
Product Racking Recommendations
PXE 100 Inspection and Planned Maintenance