PFG 600 C7000 Troubleshooting Guide
Problem | Solution |
---|---|
With switch in COOK position, the fryer is completely inoperative (no power switch light). |
Check to see if unit has voltage Check fuses Defective power switch |
With switch in COOK position, the fryer is completely inoperative (power switch light on, pump works) |
Check voltage on pins 1 and 7 on power connector, 10 VAC If voltage is present, check fuse on control board If fuse is defective, replace fuse If fuse is good, replace control |
Control operative - all lights on - primary contactor engages - no heat or pressure |
Drain Valve Open Defective Drain Switch |
Control operative - all lights on - no heat or pressure - primary contactor does NOT engage |
Check 5 amp fuse located on heat shroud - fuse OK Check voltage from center of fuse to ground - 24 VAC Defective transformer |
Control operative - all lights on - has pressure - no heat |
Connect pins 4 and 6 on the power connector If contactor eng - replace control board If contactor does engage, replace |
Control operative - all lights on - heat on - no pressure - pressure light ON. |
Connect pins 3 and 6 on the power connector If solenoid engages - defective control board If solenoid does engage - defective solenoid coil - 24 VAC |
Control operative - all lights on - heat on - no pressure - pressure light OFF | Check programming |