Error Codes and Warnings

DisplayCauseSolution
“LO”Food probe or actual temperature is below 50° F (10° C) in calibration mode onlyAllow unit to heat up, or remove food from unit
“HI”Food probe temperature above 500° F (260° C) or lower temperature 275° F (135° C), or aboveCheck the probes and heating circuit
“E-4”Control board temperature above 140° F (60° C)Check or clean cooling fans; if “E-4” persists, replace PC board
“E-6”Air probe errorCheck probe and connection at PC board
“E-41”Scrambled PC board memoryPress UP button to clear “E-41”; if “E-41” persists, replace PC board

“E-56”

Setpoint storage error

Press UP button to clear “E-56”, then turn unit off and back on; if “E-56” persists, replace PC board