Applies to:
Replacing the Transformers
Both the Express Filter transformer and the control transformer are the same part number. These components drop the line voltage to low voltage components such as, control board, Express Filter board and contactors.
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
Checkout
-
Hinge-down the control panel to access the desired transformer.
-
Pull the appropriate white connector, either from the Express Filter PC board or from the control PC board.
-
With the power on, take a voltage reading on the appropriate pins, using the chart and drawing below. If transformer proves faulty, continue with replacement instructions.
Test Points | Results |
---|---|
From pin 1 to 2 | 24 VAC |
From pin 4 to 5 | 240 VAC |
From pin 3 to 5 | 208 VAC |
Replacing
-
Disconnect power and using a 5/16 inch socket, remove the nuts securing the transformer and pull the transformer from unit.
-
Replace transformer in reverse order.
Related Content
Replacing the Element Safety Switch
Replacing the Temperature Probe
Replacing the Main Power Switch
Resetting, Checking and Replacing the Breaker
Troubleshooting EEE 15X E-5 Oil Overheating Error Code
Troubleshooting EEE 15X E-6 Temperature Probe Error Code
Troubleshooting EEE 15X E-10 High Limit Error Code
Troubleshooting EEE 15X E-18 Level Probe Error Code
Troubleshooting EEE 15X E-20A Fan Sensor Stuck On Error Code
Troubleshooting EEE 15X E-21 Heat Recovery Error Code
Troubleshooting EEE 15X E-22 No Heat Error Code
Troubleshooting EEE 15X E-31 Element Up Error Code
Reference