Troubleshooting Blank Display

-
Cross tip screwdriver
-
Multimeter
Field Troubleshooting
Does the transformer keep tripping causing the control to go dark?
-
Measure the transformer amp values.
-
If amp values are 10.5 A on 24V side and 1.5 A on 208V side, reset transformer.
-
In Tech Mode, navigate to Outputs and energize contactor.
T-18 for Evolution Elite and T-19 for LOV.
-
If one trips the transformer, that is a defective contactor.
This should resolve the issue.