Applies to:

Installing the ODS 300 Check Valve

Kit number

140078

  1. Remove pump (1) from pipe (2).

  2. Remove bracket screws (3) and discard lower tube (5) and bracket (4).

  3. Using pipe sealant on threads (6), install new tube assembly (7) onto pump.

  4. Install new bracket onto handle.

  5. Slide tube assembly (7) into new bracket and secure with thumb screw.