PFG 600 C7000 Filter Reference
The filter cycle count is a method of keeping track of when it is time to filter the oil. To determine when it is time to filter, the control adds the (fractional) number of the cycle count to a running total at the end of each cook cycle. When this total exceeds one, then the “FIL” (“FIL” within the digital display) indication is given. _,
An example of this would be as follows:
Product | Programmed Number of Cook Cycles | Cycle Count |
---|---|---|
Chicken |
4 |
1/4 |
Fish | 3 | 1/3 |
Potatoes | 2 | 1/2 |
Vegetables | 2 | 1/2 |
If the operator cooked one cycle of chicken, one cycle of fish, and one cycle of potatoes, the unit would indicate to filter since 114 I- l/3 + l/2 = 1 l/12 which is greater than one. In the event the unit cannot be filtered at the proper time the filter program mode may be bypassed. Turn the power switch to OFF for at least 5 seconds, then turn the unit back to the COOK position. Filter will be bypassed and unit will return to programmed 1st cycle.