The POWER/PUMP switch is a three way rocker switch with a center OFF position. With the switch in the POWER position the fryer operates. With the switch in the PUMP position the filter pump operates, but the unit will not heat.
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
Testing
-
Remove control panel.
-
Label and remove wires from the switch.
OFF position-should be open circuit anywhere on the switch.
Power position. Check from: #5 to #6 closed circuit and #l to #2 closed circuit
Pump position. Check from: #4 to #5 closed circuit and #3 to #2 closed circuit
Check across the jumpers on the wires of the POWER/PUMP switch. These jumpers have resistors and capacitors which may be faulty.
Replacing
-
With control panel removed, and wires off of the switch, push in on tabs on the switch to remove from the panel.
-
Replace with new switch, and reconnect wires to switch following the wiring diagram.
-