Fastron RTD Chart

Temperature (Fahrenheit) Resistance Ohms
75 95,552
100 53,020
125 30,779
150 18,587
175 11,631
200 7,527
225 5,070
250 3,441
275 2,411
300 1,729
325 1,241
330 1,170
335 1,108
340 1,050
345 995
350 942
355 892
360 840
365 791
370 750
375 711
380 675
385 640
390 604
395 568
400 540
410 488
425 421
430 401

Related Content

Information about the OFE 290 or 292 Fryer

Installing the OFE 290 or 292 Fryer

Operating the OFE 290 or 292 Fryer

Programming the OFE 290 or 292 Fryer

Troubleshooting the OFE 290 or 292 Fryer

Unpacking

Selecting the Location

Basic Operation

Operating Components

Filtering

Cleaning Nylatron Slides

Changing the Filter Envelope

Cleaning the Vat

Maintenance Schedule

Inspecting Counterweight Cables

Lubricating Lid Rollers

Product Programming

Information Mode

Replacing the Control Panel

Testing and Replacing the Fuse Holders

Troubleshooting the SMS 20 Control Countdown

Troubleshooting the SMS Control Online Projection System (OPS) Connection

Replacing the High Temperature Limit Control

Replacing the Temperature Probe

Replacing the Contactors

Replacing the Heating Elements

Testing and Replacing the Power/Pump Switch

Replacing the Drain Microswitch

Replacing the Drain Valve and Extension

Information about the 390 and 392 Fryers

Installing the 390 and 392 Fryers

Operating the 390 and 392 Fryers

Programming the 390 and 392 Fryers

Troubleshooting the 390 and 392 Fryers

Unpacking

Selecting the Location

Basic Operation

Operating Components

Changing the Filter Envelope

Filtering

Cleaning the Vat

Cleaning the Blower and Vents

Maintenance Schedule

Inspecting the Counterweight Cables

Lubricating the Lid Rollers

Cleaning Dilution Box

Cleaning the Nylatron Slides

Special Programming

Programming

Replacing the Control Panel

Replacing the Relays

Troubleshooting the SMS Control Online Projection System (OPS) Connection

Replacing the High Temperature Limit Control

Replacing the Temperature Probe

Replacing the Gas Control Valve

Replacing the Transformer

Replacing the Air Valve

Replacing the Airflow Switch

Replacing the Flame Sensor Assembly

Replacing the Ignition Modules

Replacing the Ignitor Assembly

Replacing the Blower Assembly

Testing and Replacing the Power/Pump Switch

Replacing the Drain Valve and Extension

Replacing the Drain Microswitch

Replacing the Nylatron Strips

Replacing the Lid Counterweight Cables

Information about the 580 and 582 Fryers

Installing the 580 and 582 Fryers

Operating the 580 and 582 Fryers

Programming the 580 and 582 Fryers

Troubleshooting the 580 and 582 Fryers

Unpacking

Electrical Requirements

Leveling the Fryer

Installing the Power Cord

Operating Components

Lid Operation

Basic Operation

Filling and Adding Oil

Filtering

Maintenance Schedule

Cleaning the Vat

Reversing the Lid Gasket

Cleaning Deadweight Assembly

Cleaning the Safety Relief Valve

Calibrating and Cleaning the Pressure Gauge

Basic Programming

Special Programming

SMS Control Programming

SMS Control Special Programming

Troubleshooting Guide

Testing and Replacing the Power/Pump Switch

Replacing the Control Panel

Replacing the High Temperature Limit Control

Testing and Replacing the Fuse Holders

Replacing the Contactors

Replacing the Heating Elements

Replacing the Temperature Probe

Replacing the Drain Microswitch

Replacing the Drain Valve

Replacing the Lid Counterweight Cables

Replacing the Pressure Pad

Adjusting the Lid Magnet Plate

Replacing the Solenoid

Replacing the Nylatron Slides (Cam Slide Filler)

Information about the 590 and 592 Fryers

Installing the 590 and 592 Fryers

Operating the 590 and 592 Fryers

Programming the 590 and 592 Fryers

Training on the 590 and 592 Fryers

Troubleshooting the 590 and 592 Fryers

Unpacking

Selecting the Location

Installing the Power Cord

Basic Operation

Changing the Filter Envelope

Filtering

Cleaning the Vat

Maintenance Schedule

Operating Components

Cleaning Deadweight Assembly

Cleaning the Nylatron Slides

Lubricating the Lid Rollers

Reversing the Lid Gasket

Cleaning the Safety Relief Valve

Inspecting the Counterweight Cables

Programming

Special Programming

Replacing the High Temperature Limit Control

Water Detection System

Decommissioning Fryers

Replacing the Control Panel

Testing and Replacing the Fuse Holders

PFE 590 and 591 Electronic Control Retrofit Computron 7000 to New Electronic Controls

Retrofit Control Instructions 290-590 KFC to 291-591 GM

Retrofit 292-592 Fast KFC to 291-591 Controls Instructions

FM08-481 8 Head Replacing the Control

FM08-502 8 Head Replacing KFC Control

Troubleshooting the SMS Control Online Projection System (OPS) Connection

Troubleshooting the C8000 Open Fryer Message

Replacing the Heating Elements

Replacing the Contactors

Replacing the Temperature Probe

Electric Power Cord Routing and Attachment Installation Instructions

PFE 592 (FAST Controls) to 590 (Henny Penny Controls) Retrofit Instructions

Testing and Replacing the Power/Pump Switch

Replacing the Drain Microswitch

Replacing the Drain Valve and Extension

Installing the Pump Seal Kit

Direct-Connect Retrofit Instructions (For use on fryers after SN: 290-BE0401001 & 591- LG014JC)

Filter Rinse Hose Retrofit Instructions

Replacing the Nylatron Slides (Cam Slide Filler)

Replacing the Lid Counterweight Cables

Realigning the Lid

Unpacking Instructions

PFE 590 and 591 Installing Optional Crumb Basket

Rear Cover Removal Instructions

Label Application and Location for the 8 Head Fryer

Information about the 690 and 692 Fryers

Installing the 690 and 692 Fryers

Operating the 690 and 692 Fryers

Programming the 690 and 692 Fryers

Training on the 690 and 692 Fryers

Troubleshooting the 690 and 692 Fryers

Basic Operation

Cleaning the Dilution Box

Cleaning Deadweight Assembly

Cleaning Nylatrons

Cleaning the Safety Relief Valve

Inspect Counterweight Cables

Lubricating Lid Rollers

Reversing the Lid Gasket

Filtering

Operating Components

Cleaning the Blower and Vents

Changing the Filter Envelope

Maintenance Schedule

Special Programming

Programming

Water Detection System

Unpacking

Selecting the Location

Replacing the Control Panel

Conversion From C8000 Control to KFC SMS Control

Conversion From Standard 690 Control to S/M Control

PFG 691 C8000 Retrofit Instructions

Troubleshooting the SMS Control Online Projection System (OPS) Connection

Troubleshooting the C8000 Open Fryer Message

Replacing the High Temperature Limit Control

Replacing the Temperature Probe

Replacing the Transformer

Replacing the Gas Control Valve

Replacing the Airflow Switch

Replacing the Air Valve

Replacing the Flame Sensor Assembly

Replacing the Ignitor Assembly

Replacing the Ignition Modules

Replacing the Blower Assembly

8 Head Baso Retrofit Kit

PFG-69X & OFG-39X Gas Valve Replacement Kit

Repositioning/Rewiring Air Valves for 220240V Model 690/390 fryers

Repositioning / Rewiring Air Valves for 120V Model 690/390 fryers

FM07-558 Gas Valve Replacement Kit

Ignition Module Retrofit Kits

Manifold Retrofit Kit Instructions

PFG 690/691 Ignition Module Kit

Mounting the OFG 390 and PFG 690 Vacuum Switch

PFG 690 and 691 Temperature Probe CE Instructions

Replace Gas Valve Assembly with Gas Valve and Solenoid Assembly

Replacing Gas Valve Assembly With Gas Valve and Solenoid Assembly

Air Switch Monitoring Retrofit Kit Instructions

CE Gas Valve Adjustment Instructions

Testing and Replacing the Power/Pump Switch

Replacing the Solenoid

Replacing the Drain Microswitch

Replacing the Drain Valve and Extension

PFG-690/691 & OFG-390/391 Pump Motor Relay Kit

Pan Spacer Bracket

PFG 690 and 691 Installing Filter Rinse Hose

Operating Instructions for PFG-691/OFG-391 Direct-Connect Oil System

Direct-Connect Retrofit Instructions (For use on fryers after SN: 391-LH016JC & 691-LH029JC)

Replacing the Lid Counterweight Cables

Replacing the Nylatron Slides

Replacing the Pressure Pad

Tilting the Lid Upright

Calibrating and Cleaning the Pressure Gauge

I-Beam Cable Hole Plug Installation

Replace Nylatron Slides on PFG 690 and 691

PFG 690 and 691 Lid Cable Replacement

Realigning the Lid

Replacing the Casters

PFG 690 to 692 Retrofit Kit

Installing Optional Crumb Basket

PFG 690 Stabilizer Retrofit Instructions

Reference

Specifications

Wiring Diagrams

Error Codes

1000 Ohm Chart

Specifications

Error Codes

Wiring Diagrams

Specifications

Error Codes

Wiring Diagrams

Specifications

Error Codes

Wiring Diagrams

PFE 590 and 592 Inspection and Planned Maintenance

PFE 590 and 592 KFC Annual Inspection Certification

Error Codes

Specifications

PFG 690 Wiring Diagrams

PFG 690 and 692 Inspection and Planned Maintenance

PFG 690 and 692 KFC Annual Inspection Certification