Cleaning the Safety Relief Valve
![]() | To avoid severe burns, do not tamper with safety relief valve while operating fryer. |
![]() | To avoid serious personal injury, do not tamper with safety relief valve. Tampering with this valve will void agency approvals and appliance warranty. |
This valve is factory preset to open at 14½ psi. (999 mbar).
Do not use a pipe wrench. Use thread sealant sparingly.
Use a wrench to remove pressure gauge.
Use a wrench to loosen the valve from the pipe tee, turn counterclockwise to remove.
Clean the inside of the pipe tee with hot water.
Immerse the safety relief valve in a soapy water solution for 24 hours. Use a 1:1 dilution rate. The valve cannot be disassembled It is factory preset to open at 14-1/2 pounds of pressure. If it does not open or close, it must be replaced.
Turn the safety relief valve towards the rear of the fryer when reinstalling the relief valve.