Applies to:

Stats Mode
This mode allows a technician to view advanced information on the operation of the fryer and controls.
-
Press and hold the program button for 5 seconds until “LEVEL 2”, followed by, “SP PROG” and “ENTER CODE” show in the display.
-
Press the program button 5 times and “STATS” and “ENTER CODE” flash in the left display.
-
Enter code 1, 1, 2, 2, 1, 1, 2, 2 (first 2 product buttons).
-
“ST-1 STATS LAST RESET ON...” flashes in the left display and the date shows in the right display. Use the up and down arrow buttons to select the steps.
If a bad code is entered, a tone sounds and “BAD CODE” shows on the display. Wait a few seconds, the controls revert back to the cook mode, and repeat the above steps.
Press and hold the program button at anytime to return to normal operation.
| Program Code | Description |
|---|---|
| ST-1 | Stats Last Reset Date |
| ST-2 | Fryer Total Running Hours |
| ST-3 | Left Vat Melt Cycle Hours |
| ST-4 | Left Vat Cook Cycle Hours |
| ST-5 | Left Vat Idle Hours |
| ST-6 | Right Vat Melt Cycle Hours |
| ST-7 | Right Vat Cook Cycle Hours |
| ST-8 | Right Vat Idle Hours |
| ST-9 | Power-Ups Count |
| ST-10 | Error Counts |
| ST-11 | Left Vat Heat On Hours |
| ST-12 | Right Vat Heat On Hours |
| ST-13 | Highest Left Vat Oil Temperature |
| ST-14 | Highest Right Vat Oil Temperature |
| ST-15 | Highest CPU Temperature |
| ST-16 | System RAM Fade Count |
| ST-17 | Cook RAM Fade Count |
| ST-18 | Product RAM Fade Count |
| ST-19 | Stat RAM Fade Count |
| ST-20 | RAM Data Error Count |
| ST-21 | Data Total Loss Count |
| ST-22 | User Initialization Count |
| ST-23 | Automatic Initialization Count |
| ST-24 | Cooks Count per Product |
| ST-25 | Cook Cycle Stop Counts |
| ST-25A | Number Of Stops In First 30 Seconds |
| ST-25B | 0 |
| ST-25C | 0 |
| ST-25D | Complete Cook Cycles Counted |
| ST-26 | Reset All Stats |
Related Content
Info Button and Filter Button Statistics
Preventative Maintenance Schedule
Changing Auto lift Basket Operation