During normal operation, the ignition modules send 24 volts to the ignitors and gas control valve. If a module does not sense a pilot flame, the module starts the ignition process again. But, if a pilot light goes out for longer that 15 seconds, or it goes out 3 times within 15 seconds, the module keeps the 24 volts from reaching the gas control valve. The burners shut down.
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Open the left door and using a crosshead screwdriver, remove the screws securing the module cover and remove cover.
-
Label and pull the wires from the module.
-
Using a 3/8 inch socket or nut driver remove the nuts securing the module and remove module from unit.
-
Install new module in reverse order and restore power to the unit.