Replacing the Pressure Transducer
This component controls the AIF filter pump by sensing the pressure in the expansion chamber. Voltage range is 0.5 to 4.5 VDC, corresponding to a pressure range of 0 to 30 PSIG A measured pressure below -1.5 PSI or above 32 PSI may indicate a failed transducer, it has become disconnected, or a clogged expansion chamber.
Viewing the Pressure:
-
Press ◄ ► at the same time and “*INFO* *MODE*” displays, followed by “1. E-LOG”. Press ► until “15. AIF” displays.
-
Press ▼ until “PRESSURE SENSOR” displays on the left.
-
Press X button to show pressure in PSI.
An over-pressure issue can also indicate a return valve failing to open, instead of a faulty transducer or a clogged chamber. Extra long fill times or oil bubbling at the end of an AIF cycle may be signs of a clogged expansion chamber or faulty transducer.
In case of a clogged expansion chamber, remove the cleanout plugs at each end of the chamber to clean the obstructions inside the chamber.
Replacing
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Remove the left side panel.
-
Pull-out on the clip, while pushing up on the wire harness connector, at the top of the transducer, to remove wires.
-
Using a 1-1/16 inch wrench, remove the transducer from the expansion chamber.
-
Using pipe thread sealant, install new transducer in reverse order and restore power to the unit.