Replacing the Heat Contactor
|
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
The transformer reduces voltage down to accommodate those components with low voltage.
-
Ensure power is removed from the fryer.
-
Use a cross-tip head screwdriver to remove two screws in in the front of the control panel.
-
Rotate the panel down and remove if necessary.
-
Remove the wires from the contactor.
-
Use a cross-tip head screwdriver to remove the screws securing the high limit module.
-
Install the new module, reconnect the wires, and install the control panel.
-
Test the new high limit module to ensure it works properly.
Related Content
Replacing the Momentary Switch
Replacing the Primary Contactor
Replacing the Heating Element Assembly
Replacing the Temperature Level Probe
Replacing High Limit Thermocouples
Troubleshooting the Solid State High Limit
Temperature Probe Gauge Instructions