Replacing the Radiant Heater

To avoid electrical shock or property damage, move the power switch to OFF and disconnect power.

  1. Remove electrical power supplied to the cabinet.

  2. Remove the four screws located at the bottom of the heater housing - two on each end.

  3. Remove the electrical wires from the heater. Check with an ohmmeter across end terminals. The ohm reading should be as follows:

    Model/Volts Ohms

    HCW-3 (208 volts)

    43 ohms

    HCW-3 (230 volts) 53 ohms
    HCW-5 lower (208 volts) 43 ohms
    HCW-5 lower (230 volts) 53 ohms
    HCW-5 upper (208 volts) 108 ohms

    HCW-5 upper (230 volts)

    132 ohms

    HCW-8 lower (208 volts) 22 ohms
    HCW-8 lower (230 volts) 26 ohms
    HCW-8 upper (208 volts) 54 ohms
    HCW-8 upper (230 volts) 66 ohms

    If a heater checks defective, replace it by continuing with this procedure.

  4. Slide the brackets off the defective heater and install brackets on new heater.

  5. Install the new heater in reverse order.

  6. Turn on the power supply at the breaker box.