HCW 8 Single Phase Field Retrofit Kit
Kit number
14182
Estimated Time
1 to 1.5 Hours
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
The following wires share the same terminal:
-
#9 and #49,
-
#10 and #99
-
#11 and #50
-
#44 and #45
-
#64 and #65
-
#12 and #51
-
Remove electrical power supplied to the cabinet.
-
Remove the upper and lower side panels on the control side of the unit.
-
Remove the two water heater cover plates closest to the contorl panel.
-
Remove all existing wire ties.
-
Replace the wires in the unit with the wires in the kit.
-
Disconnect water heater wires #26 and #30, #27, #31, #71, and #30, #72 and #31. Re-connect these wires using the larger wire and the larger wire nuts, provided in the kit.
-
Cut wire #10 from the power indicator light, where it plugs into the switch.
-
Strip this wire and attach the short wire on the new #10 wire from the kit, to the indicator light. Use the small wire nut removed earlier.
-
Plug the new #10 into the swtich.
-
Use the provided wire ties to neatly dress the heater wires, then replace the access panels.
-
Continue replacing the wires in the control panel area.
-
Use the provided wire ties to neatly dress the wires in the control panel area.
-
Replace the upper and lower side panels.
-
Unit is now ready for operation.