Disposing to an ODS 300

Overview

Follow the procedure for manually disposing oil in a PXE/OXE Velocity series fryer using an ODS-300 shuttle.

Manually Disposing Oil

* ODS-300 shuttle will not engage fryer filter pan switch

** ODS-300 shuttle does not have enough capacity to dispose a full vat of oil. Full disposal of oil will require two trips.

  1. Press and hold menu button. > 1. Filter > 7. DISPOSE

  2. Remove filter pan from fryer and insert ODS-300 shuttle in place.

  3. * Confirm shuttle is in place with YES button.

  4. Press and hold DRAIN button to open drain valve. Releasing DRAIN button will close drain valve.

  5. ** Release DRAIN button to close drain valve with approximately half of the oil drained into shuttle.

  6. Remove shuttle from fryer and discard of oil into approved tank.

  7. Insert empty shuttle and continue draining vat complete by holding DRAIN button.

  8. Release DRAIN button when vat is empty to close drain valve. Press NEXT button to continue.

  9. Purge oil oil from lines and fittings by press and holding PUMP button for approximately 10 seconds. Press NEXT button to continue.

  10. Press OPEN DRAIN button to empty remaining oil during Wipe Vat stage. Wipe vat clean then press CLOSE DRN button.

  11. Remove shuttle from fryer and discard of oil into approved tank.

  12. Insert filter pan and fill vat with new oil to resume normal operation.