Applies to:
The POWER/PUMP switch is a three way rocker switch with a center OFF position. With the switch in the POWER position the fryer operates. With the switch in the PUMP position the filter pump operates, but the unit will not heat.
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
Testing
-
Remove control panel.
-
Label and remove wires from the switch.
OFF position-should be open circuit anywhere on the switch.
Power position. Check from: #5 to #6 closed circuit and #l to #2 closed circuit
Pump position. Check from: #4 to #5 closed circuit and #3 to #2 closed circuit
Check across the jumpers on the wires of the POWER/PUMP switch. These jumpers have resistors and capacitors which may be faulty.
Replacing
-
With control panel removed, and wires off of the switch, push in on tabs on the switch to remove from the panel.
-
Replace with new switch, and reconnect wires to switch following the wiring diagram.
-
Replace the control panel.