Applies to:
Replacing the Water Heater High Limit

11/32" socket or wrench
![]() |
To avoid electrical shock or property damage, disconnect power before installing or servicing equipment. A qualified technician must perform the service procedures. |
![]() |
HOT WATER To avoid burns, use PPE when handling overflow tube and draining unit. |
-
Disconnect water supply.
-
While wearing heat resistant gloves or using a grasping tool, remove overflow tube and allow water to drain from pan.
-
Remove screws and lower access panel from rear of unit.
-
Using an 11/32" socket or wrench, remove the nuts securing the water heater cover and remove cover.
-
Remove wire from high limit.
-
Check across the terminals for continuity. If the unit is not heating, the circuit should be closed, or read no resistance. If high limit is defective, continue onto step 6.
-
Remove the 2 nuts securing the high limit and remove high limit. Leave the standoffs in place.
-
Install new high limit in reverse order. Unit is now ready for use.