Applies to:

Replacing the Solenoid Valve and Water Strainer

To avoid electrical shock or property damage, disconnect power before installing or servicing equipment. A qualified technician must perform the service procedures.

HOT WATER

To avoid burns, use PPE when handling overflow tube and draining unit.

  1. While wearing heat resistant gloves or using a grasping tool, remove overflow tube and allow water to drain from pan.

  2. Remove screws and lower access panel from rear of unit.

  3. Disconnect lead wires from solenoid valve.

  4. Using a flat blade screwdriver, loosen hose clamp and remove hose from barb fitting.

  5. Using a crosshead screwdriver, remove 4 screws and remove bracket, valve, and strainer assembly from under cabinet.

  6. Using a crosshead screwdriver, remove 2 screws and valve.

  7. Using a 1" wrench, loosen bulkhead adapter nuts and remove bracket.

  8. Disassemble parts as needed to repair or replace strainer or valve.

  9. Reassemble repaired parts and install in reverse order.