Troubleshooting Blank Display

-
Cross tip screwdriver
-
Multimeter
Field Troubleshooting
Does the transformer keep tripping causing the control to go dark?
-
Measure the transformer amp values.
-
If amp values are 10.5 A on 24V side and 1.5 A on 208V side, reset transformer.
-
In Tech Mode, navigate to Outputs and energize contactor.
T-18 for Evolution Elite and T-19 for LOV.
-
If one trips the transformer, that is a defective contactor.
This should resolve the issue.
Related Content
Replacing the Express Filter PC Board
Replacing the Main Power Switch
Replacing the Control Panel and Menu Card
Resetting, Checking and Replacing the Breaker
Replacing the EEE 153 and 154 Time Delay Relays
Smart Touch Software Installation Instructions
Troubleshooting an E-60 AIF Communication Failure
Wendy’s Autonomous Power Switching Circuit Field By-Pass