Applies to:
Replacing the JIB Pump
This pump keeps the vats filled and is used in the Oil Guardian™ process.
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Remove the right side panel.
-
Using a 1 inch wrench, loosen fitting on right side of pump.
-
Remove the hose from the pump.
-
Remove the 4 bolts securing the bottom of pump.
-
Disconnect the wires in the rear of the pump and pull assembly from fryer.
-
Pull fittings from faulty pump and attach the fittings to the new pump in the same orientation.
-
Install new pump assembly in fryer, in reverse order and then reconnect power to fryer.
Related Content
Replacing the Flange Mount Filter Pump and Motor
Replacing the Filter Motor Relay
Replacing the Filter Pan Switch
Adjusting the Drain Valve Actuator
Troubleshooting the Check Pan Message on Evolution Elite Fryers
Replacing the EEG Fryer Generation 4 Selector Valve Motor
Troubleshooting EEG 15X E-15 Drain Open Error Code
Troubleshooting EEG 15X Oil Not Pumping Error Code
Reference