Applies to:
Replacing the Blower
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Remove electrical power supplied to the unit.
-
Remove the lower back shroud.
-
Using a crosshead screw, remove the two screws that secures the blower to the flue. One screw is located on the back side of the flue.
-
Cut zip ties that are holding the wires to the blower. Remove the wire nuts from the wires.
-
Remove blower.
-
Reconnect new blower wires to the existing wires with wire nuts.
-
Tighten the new blower onto the flue with the two screws.
-
Zip tie wires back to the blower.
Related Content
Replacing the High Temperature Limit Control
Replacing the Temperature Probe
Replacing the Air Pressure Switches
Replacing the Main Power Switch
Troubleshooting EEG 25X E-4 Control Overheating Error Code
Troubleshooting EEG 25X E-5 Oil Overheating Error Code
Troubleshooting EEG 25X E-6 Temperature Probe Failure Error Code
Troubleshooting EEG 25X E-10 High Limit Error Code
Troubleshooting the EEG 25X E-18 Level Probe Failure Error Code
Troubleshooting EEG 25X E-20A Fan Sensor Stuck On Error Code
Troubleshooting EEG 25X E-20B No Draft Check Fan Error Code
Troubleshooting EEG 25X E-20D Ignition Failure Error Code
Troubleshooting EEG 25X E-22 No Heat Error Code
Reference