Applies to:

Replacing the JIB Pump

This pump keeps the vats filled (Auto Top-Off)

To avoid electrical shock or property damage, move the power switch to OFF and disconnect power.

  1. Remove the right side panel.

  2. Using one inch wrench, loosen both fitting on each side of pump.

  3. Using a crosshead screwdriver, remove the four screws securing the bottom of pump.

  4. Disconnect the wires in the rear of pump and pull assembly from fryer.

  5. Pull fittings from faulty pump and attach the fittings to new pump, in the same orientation.

  6. Install new pump assembly in fryer, in reverse order and then reconnect power to fryer.