Replacing the Air Pressure Switch
The vacuum switch senses the flow of air coming from the blower. If the airflow is reduced below a set amount, the switch cuts power to the control valve, which shuts the burners down.
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Air switches are located on the rear of the fryer. Using a crosshead screwdriver, remove the 2 screws securing the outer cover and remove cover.
-
Label and pull wires from switch.
-
Pull tube from switch and using a crosshead screwdriver, remove 2 screws securing the switch to the bracket and remove switch.
-
Install new switch in reverse order and restore power to unit.