Troubleshooting the E-41S System Set Lost Error Code
Overview
The E-41S system data loss error occurs when there is an internal loss of system settings. If this error is detected, the system settings are reset to their default values. Users can acknowledge this message and continue using the fryer. However, if the error persists, further steps are required to resolve the issue.
Call Avoidance
To avoid unnecessary service calls, follow these steps to troubleshoot and resolve the E41S system data loss error:
Reflash Software
-
Prepare USB with latest software release. Please see the software update instructions to prepare a USB properly.
-
Enter the main menu by pressing and holding the program button for 3 seconds.
-
Choose option #3, USB Data.
-
Choose option #4, Reflash Software.
-
Plug in the USB drive containing the software update.
-
Select the software file you want to load.
-
Once the update is complete, exit the menu and remove the USB.
Field Troubleshooting
If call avoidance steps do not resolve the issue, proceed with the following field troubleshooting steps.
Recommended Parts:
-
USB drive (with the latest software update)
Recommended Tools:
Basic hand tools
Troubleshooting
If after performing a software update the issue persists, replace the control.