Troubleshooting the E-46 through E-54 Control Fail Error Code
Overview
The controls are known for their reliability and efficiency; however, they can occasionally experience internal control and failures that require a control replacement. The errors listed below represent an internal failure and likely require a control replacement.
Error Display
-
E-46C Internal Memory Error
-
E-46W Data Save Operation Error
-
E-47A Temperature Chip Failure
-
E-47B Sensor Chip Failure
-
E-47M Both Temp and Sensor Chip Failure
-
E-54C CPU Circuit Failure
-
E-54D Driver Safety Circuit Failure
-
E-54L Low Speed Oscillator Driver Failure
Call Avoidance
To help the end user resolve the issue without a service call:
-
Turn off the fryer at the main power switch.
-
Disconnect the power cord from the outlet.
-
Wait for 1 minute to ensure complete power discharge.
-
Reconnect the power cord to the outlet.
-
Turn the fryer back on using the main power switch.
Field Troubleshooting
If call avoidance steps do not resolve the issue, proceed with the following field troubleshooting steps.
Recommended Parts:
Recommended Tools:
Basic hand tools
Troubleshooting
If cycling the power doesn't resolve the issue, inspect the control.
-
Check for visible signs of damage or wear.
-
Replace control
Related Content
Troubleshooting the E-4 CPU Too Hot Error Code
Troubleshooting the E-41P Product Data or Multiple Product Data Lost Error Code
Troubleshooting the E-41S System Set Lost Error Code
Troubleshooting the E-61 Communication Error Code