Review Usage
-
Press and hold the Function button for two seconds until “REG PROGRAM” shows in the display. As soon as “REG PROGRAM” shows in the display, press and release the Function button 1 time until “REVIEW USE” shows in the display.
-
“DAILY” shows in the display. Press any of the Product buttons to view the usage of that product. Press and hold the Function button to exit Special Program mode.
Reset Usage
-
Press and hold the Function button for two seconds until “REG PROGRAM” shows in the display. As soon as “REG PROGRAM” shows in the display, press and release the Function button 2 times until “RESET USE” shows in the display.
-
When “CODE” shows in the display, press 1-3-5. “DAILY” will show in the display. Press any of the Product buttons to reset them to 0.
Factory Presets (F/C, Gas/Electric, Speaker Volume, Speaker Frequency, Codes, Initialize System)
-
Press and hold the Function button for two seconds until “REG PROGRAM” shows in the display. As soon as “REG PROGRAM” shows in the display, press and release the Function button until “FAC PRESET” shows in the display.
-
When “CODE” shows on the display, enter 2957. “DEG” and “MODE” flashes in the display. Press any of the product buttons to toggle from ºF to ºC, vice versa.
-
Press and release the Function button and “TYPE” and “FRYR” flashes in the display. Press any of the product buttons to toggle from “GAS” to “ELEC”, or vice versa.
-
Press and release the Function button until “SPKR” and “VOL” flashes in the display. The volume can be changed from 01 to 10, 10 being the loudest.
-
Press and release the Function button until “SPKR” and “FREQ” flashes in the display. The frequency can be set from 100 to 2000.
-
Press and release the Function button until “INTITIALIZE SYSTEM” scrolls across the display. Press and hold any of the Product buttons and the display counts down from 5. Once the display counts down, release the Product button, and the controls reset, but the programmed settings remain the same.
Before attempting to change the other modes in the Factory Preset mode, please call Technical Service Department at Henny Penny.
Tech I/O Mode
-
Press and hold the Function button for two seconds until “REG PROGRAM” shows in the display. As soon as “REG PROGRAM” shows in the display, press and release the Function button 4 times until “TECH I-O” shows in the display.
-
When “CODE” shows in the display, press 2-4-6. “HEAT’, “PRESSURE”, and “PUMP” will show, alternately, in the display. Also, the LEDs over 1, 2 and 3 will flash alternately.
-
To test the heat circuit, press and hold the 1 button.
-
To test the pressure system, press and hold the 2 button.
-
To test the pump system, press and hold the 3 button.
Appliance Test
Press and hold the Function button for two seconds until “REG PROGRAM” shows in the display. As soon as “REG PROGRAM” shows in the display, press and release the Function button 5 times until “APPL TEST” shows in the display.
With the power switch on, the display will show “CURR=”, along with the time it took the unit to heat from 250º to 300º F (121ºto 149º C) . This is normally recorded from the initial heat up in the morning.
Heat Control
-
Press and hold the Function button for two seconds until “REG PROGRAM” shows in the display. As soon as “REG PROGRAM” shows in the display, press and release the Function button 6 times until “HEAT CNTRL” shows in the display.
-
When “CODE” shows in the display, press 1-2-3-4. “MELT”, “EXIT”, and “TEMP” will flash in the display, along with the shortening temperature at which the unit will exit the melt cycle. This should be set at 180º F (82º C), and should not be changed until the factory is consulted.
-
Press and release the Function button and ”MELT”, “CYCLE”, and “100s” shows alternately in the display, along with the period (pulse) length of 4000. This should not be changed until the factory is consulted.
-
Press and release the Function button twice and “MELT”, “ON-”, “TIME”, and “100s”, shows alternately in the display, along with the length of time the heat is on. This should be set at 1700, and should not be changed until the factory is consulted.
-
Press and release the Function button three times and “COOL”, “SET-”, and “POINT” shows alternately in the display, along with the temperature at which the control exits the melt cycle. This is set at 250º F (121º C), and should not be changed until the factory is consulted.
-
Press and release the Function button four times and “AUTO”, and “IDLE” shows alternately in the display, along with “OFF”. This should not be changed until the factory is consulted.
-
Press and release the Function button five times and “AUTO”, “IDLE”, and “MMSS” shows alternately in the display, along with “0:00”. This should not be changed until the factory is consulted.
-
The last 3 functions in the Heat Control mode are used by the factory only, and should not be changed.
Related Content
C2000 Special Programming for Wendy's
PFG 600 C7000 One Button Programming
C8000 Programming the Products
C8000 Program Settings Worksheet
Setting the Clock for Chick-fil-A
PFG 600 Diagnostic Mode for Chick-fil-A
Second Level Programming for Chick-fil-A
C8000 Copying and Erasing the Product Settings
Reference