CFE 410/420 Troubleshooting the Voltage Conversion
Overview
To convert a CFE 410/420 from 208VAC to 240VAC or 480VAC, follow the procedure below.
![]() |
Shock Hazard To avoid electrical shock or property damage, disconnect power before installing or servicing equipment. Lowering the control board exposes the technician to 240 VAC electricity inside the fryer. |
Converting from 208VAC to 240VAC or 480VAC
-
For 480V only: add the 480V transformer 19923.
-
Swap the Orange and Red wires on the control board transformer.
-
Swap the Orange and Red wires on the AIF board transformer.
-
Install correct voltage circuit breakers behind the control board.
-
Install correct voltage elements.
Related Content
Replacing the High Limit Module
Temperature Probe Gauge Instructions
CFE 410/420 Troubleshooting the E-5 Oil Overheating Error Code
CFE 410/420 Troubleshooting the E-6 Temperature Probe Error Code
CFE 410/420 Troubleshooting the E-10 High Limit Error Code
CFE 410/420 Troubleshooting the E-20A Fan Sensor Stuck On Error Code
CFE 410/420 Troubleshooting the E-26 Heat Amps Locked On Error Code
CFE 410/420 Troubleshooting the E-27 Amps Too Low Error Code
CFE 410/420 Troubleshooting an E-29 Error Code
CFE 410/420 Troubleshooting the W-1 Low Voltage Error Code
CFE 410/420 Troubleshooting the W-2 Slow Heating Error Code
CFE 410/420 Troubleshooting the W-3 Was Not Ready Error Code
CFE 410/420 Troubleshooting the W-4 Slow Cooking Error Code
CFE 410/420 Troubleshooting the W-5 Slow Cooking Error Code
CFE 410/420 Troubleshooting the W-6 Slow Cooking Error Code
CFE 410/420 Troubleshooting the W-7 Low Amps Error Code
CFE 410/420 Troubleshooting the W-9 Discard Product Error Code
CFE 410/420 Troubleshooting the E-92 24V Current Limiter Fuse Tripped Error Code
Reference