Replacing the Fuse and Fuse Holder

multimeter or ohmmeter
crosshead screwdriver
5/16” socket
![]() |
To avoid electrical shock or property damage, disconnect power before installing or servicing equipment. A qualified technician must perform the service procedures. |
Replacing the Fuse
-
Unscrew fuse holder cap counterclockwise to access fuse
-
To check fuse, use a multimeter, or continuity tester, and put leads on each end of fuse. If meter shows circuit is closed, fuse is good. Replace fuse with a 15 amp fuse (20 amp fuse-CE), if meter shows circuit is open.
Replacing the Fuse Holder
-
Remove the crosshead screws securing the bottom, rear cover and let hinge down.
-
Pull wires from fuse holder terminals.
-
Using 5/16” socket remove nuts securing fuse holder and pull holder from unit
-
Install new fuse holder in reverse order.