CW 216 Three Phase to Single Phase Conversion
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Disconnect terminal block end from the "L2" block and reconnect wire to the "L1" terminal block.
-
Disconnect terminal block end from the "L3" block and reconnect wire to the "L2" terminal block.
-
Disconnect terminal block end from the "L2" block and reconnect wire to the "L1" terminal block.
-
Disconnect terminal block end from the "L3" block and reconnect wire to the "L2" terminal block.
-
Remove power switch 69 wire from unit.
-
Remove power switch 70 wire from unit.
-
Remove contactor 6 wire from unit.
-
Disconnect terminal block end from the "L3" block and reconnect wire to the "L2" block.
-
Leave wire as is.
-
Disconnect contactor end and move connection to upper contactor terminal. Wires marked "9" and "10" should have a common termination at the contactor terminals.
-
Leave wire as is.
Wiring should now agree with attached single phase diagram.
CW 216, 240 VAC, 50-60Hz, 1 Phase Wiring Diagram
Neither "L3" terminal blocks should have any wire connections.