Applies to:
Conversion from 208V to 240V
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
To convert from 208V to 240V on the PXE or OXE 100:
-
Replace the heating elements.
-
Remove the 5 wire jumper between the transformer and the control connector.
-
Plug the connector from the transformer directly into the control.
Related Content
Replacing the High Limit Thermocouples
Replacing the Primary Contactor
Temp/Level Probe Fitting Replacement
High Limit Protection Probe Installation (CE Version built prior to 5/2020, ALL Versions after)
High Limit Protection Probe Installation (UL Version built prior to 5/2020)
Velocity High Limit Adjustment Instructions
Reference