Applies to:

Velocity High Limit Adjustment Instructions

Estimated Time

30 Minutes

    To avoid electrical shock or property damage, move the power switch to OFF and disconnect power.

  1. Drain oil from unit.

  2. Loosen both spreader bar assemblies on the front side of the heat elements.

  3. Loosen upper and lower high limit clamps.

  4. Use a flat head screwdriver to gently spread elements.

  5. Slide spreader assembly and high limit spacer toward pot wall slightly.

  6. Position high limit brackets such that the end of the probes protrude .125 in. (3.2 nm) past the high limit clamp.

  7. Re-tighten clamps.

  8. Slide spread assembly and high limit spacer toward vat interior until the high limit spacer contacts the high limit clamp.

  9. Tighten spreader assemblies, ensure the heating elements are aligned.

  10. Unit is now ready for operation.

Related Content

Replacing the High Limit Thermocouples

Replacing the High Limit

Replacing the Primary Contactor

Replacing the Heat Contactor

Temp/Level Probe Fitting Replacement

High Limit Protection Probe Installation (CE Version built prior to 5/2020, ALL Versions after)

High Limit Protection Probe Installation (UL Version built prior to 5/2020)

Installing the Pump Seal Kit

Lid Latch Adjustment or Replacement

Armored Cable Grounding Installation Instructions for Australia

ZigBee Radio Communication Kit

Replacing the Filter Valve

Velocity Nylatron Vertical Filler Strips Installation Instructions

Selector Valve Motor/Encoder Replacement

Velocity Deadweight Orifice Clean-out Tool Installation and Maintenance

Velocity Lid Cable Replacement

Instructions to replace PXE Interlock Latch Pivot Pin

Front Dispose Addition (for Bulk Oil Units)

Remove Selector Valve to ATO flex tube

Label Replacement Instructions

Menu Card Removal Replacement Instructions

Save and Load Setpoint Instructions

Re-flashing Instructions

Flexible Line Replacement Kit (Formed Tube), (Standard, Bulk-Oil Fryer)

Flexible Line Replacement Kit (Formed Tube), (Standard, NON Bulk-Oil Fryer)

JIB Pump Retrofit

Replacing the High Limit

Replacing the High Limit Thermocouples

Replacing the Heat Contactor

Velocity Steam Box Swap-out Instructions

Lid Handle Replacement Instructions

Securing Latch Pin Block

Lid Latch Replacement

Save PXE 100 Setpoints

Add pressure gauge to PXE unit Instructions (Japan / Hong Kong)

Add pressure gauge to PXE unit Instructions

PXE Pump Motor Installation

Reference

Specifications

Menu Structure

Heating Times

Product Racking Recommendations

Error Codes

OXE 100 Plumbing Diagrams

OXE 100 Wiring Diagrams

OXE 100 Annual Inspection

OXE 100 KFC Annual Inspection Certification

Specifications

Menu Structure

Heating Times

Product Racking Recommendations

Error Codes

PXE 100 Plumbing Diagrams

PXE 100 Wiring Diagrams

PXE 100 Inspection and Planned Maintenance

PXE 100 KFC Annual Inspection Certification