Replacing the High Limit
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
The upper module controls the lower thermocouple. The lower module controls the upper thermocouple.
-
Lower the control board by performing the removal procedure.
-
Locate the faulty high limit module on the left-hand (from the front) side wall.
-
Mark all the wire locations, and then disconnect all the wires.
-
Use a 3/8 inch socket or nut-driver to remove the nuts.
-
Remove the two metal lock strips, and then slide the old high limit module off of the mounting studs.
-
Slide the new high limit module on to the mounting studs, and then place the two metal lock strips onto the studs.
-
Secure in place with a 3/8 inch socket or nut-driver, and then reconnect the wires.
-
Install the control board by performing the installation procedure.