Applies to:
Replacing the Heat Contactor
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Lower the control board.
-
Mark the location of the wires.
-
Use a crosshead screwdriver to remove the:
-
A1 and A2 blue wires from the contactor.
-
1L1, 3L2, and 5L3 wires from the side of the contactor.
-
2T1, 4T2, and 6T3 wires from the side of the contactor.
-
-
Use a 3/8 inch nut-driver to remove the nuts that secure the contactor to the shroud.
-
Lift up on the contactor and remove it from the studs.
-
Place the new contactor on to the studs, and then use a 3/8 inch nut-driver to secure in place.
-
Use a crosshead screwdriver to install the:
-
2T1, 4T2, and 6T3 wires from the side of the contactor.
-
1L1, 3L2, and 5L3 wires from the side of the contactor.
-
A1 and A2 blue wires from the contactor.
-
-
Install the control board.
Related Content
Replacing the High Limit Thermocouples
Replacing the Primary Contactor
Temp/Level Probe Fitting Replacement
High Limit Protection Probe Installation (CE Version built prior to 5/2020, ALL Versions after)
High Limit Protection Probe Installation (UL Version built prior to 5/2020)
Velocity High Limit Adjustment Instructions
Reference