Applies to:
The airflow switch senses the flow of air coming from the blower. If the airflow is reduced below a set amount, the switch will cut power to the control valve, which shuts the burners down.
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
NOTICE - |
To avoid property damage, do not tamper with this component. It is factory sealed and should not be adjusted. |
-
Remove the electrical power supplied to the unit.
-
Remove the control panel.
-
Remove screws securing air switch to the frame, and remove switch.
-
Pull hose from switch from under fryer.
Mark wires before removal to insure new transformer is wired correctly.
-
Disconnect wires from switch.
-
Install new airflow switch in reverse order.