The blower motor circulates air into the burner area to create the correct heat for the fryer. If the blower fails, a sensor will shut the gas control valve down.
|
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Remove the electrical power supplied to the unit.
-
Remove back shroud and right side panel.
-
Remove the tube from the blower.
The blower tube will slide out of the bracket, instead of bolted, on the newer fryers.
-
Remove the bracket from the frame.
-
Remove the flue.
-
Disconnect wires at junction box.
-
Remove the blower from the plate.
-
Replace new blower in reverse order of procedures.