Replacing the Blower Wheel
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Loosen set screw using a hex-key.
-
Attach wheel puller to OD of wheel hub by tighten 3 hex head bolts down with 1/ 2 inch wrench, making sure to keep the puller centered along the wheel/shaft axis.
-
Turn screw to remove the wheel from the motor shaft.
-
File down the burr on the shaft left by the set screw, to allow wheel to slide onto shaft freely.
-
Install wheel with hub set to end of shaft and tighten set screw.
-
Turn on blower and verify that pressure is 1.7 inwc at 60 Hz (1.4 inwc at 50 Hz) or greater.
If less than 1.7 inwc at 60 Hz (1.4 inwc at 50 Hz) verify that flue is not obstructed and clean as needed to achieve 1.7 inwc.
Related Content
Replacing the Main Power Switch
Replacing the High Temperature Limit Control
Replacing the Temperature Probe
Replacing the Air Pressure Switches
Troubleshooting EEG 16X and 24X E-5 Oil Overheating Error Code
Troubleshooting EEG 16X and 24X E-6 Temperature Probe Failure Error Code
Troubleshooting EEG 16X and 24X E-10 High Limit Error Code
Troubleshooting EEG 16X and 24X E-20A Fan Sensor Failure Error Code
Troubleshooting EEG 16X and 24X E-20B No Draft Check Fan Error Code
Troubleshooting EEG 16X and 24X E-20D Ignition Failure Error Code
Troubleshooting EEG 16X and 24X E-22 No Heat Error Code
Reference