Replacing the High Temperature Limit Control
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Remove electrical power supplied to the unit.
-
Lower the control board.
-
Using a 5/16 inch wrench, remove the two nuts connecting the heat shield covering the high limit control.
-
Mark and disconnect the wires located on the high limit control.
-
Using a 3/8 inch wrench, remove the nuts.
-
Remove the clamp bars.
-
Using a 5/16 inch wrench, remove the two nuts on the high limit bracket and then slide the high limit control off of mounting studs.
-
Install the new control in reverse order.