Replacing the Blower
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Remove electrical power supplied to the unit.
-
Remove the lower back shroud.
-
Using a crosshead screw, remove the two screws that secures the blower to the flue. One screw is located on the back side of the flue.
-
Cut zip ties that are holding the wires to the blower. Remove the wire nuts from the wires.
-
Remove blower.
-
Reconnect new blower wires to the existing wires with wire nuts.
-
Tighten the new blower onto the flue with the two screws.
-
Zip tie wires back to the blower.