Replacing the JIB Pump
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Remove electrical power supplied to the unit.
-
Remove the lower back shroud.
-
Remove blower. See Replacing the Blower.
-
Using an adjustable wrench, remove the flex line from the elbow (1).
-
Loosen the hose clamp with a flat blade screw driver and disconnect the hose.
-
Use a 3/8 inch socket or wrench and remove the four nuts and washers (2) from the pumps feet.
-
Pull the pump off of the studs.
-
Remove the wire nuts.
-
Wire the new pump into the existing wires.
-
Place the pump onto the studs. Be sure to have the shield box (3) in place on the studs before placing the pump onto studs.
-
Tighten the pump nuts and washers onto the feet of the pump.
-
Reconnect fittings.
-
Replace blower.