Applies to:
Replacing the AIF Pump
This pump keeps the vats filled (Auto Top-Off)
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Remove the right side panel.
-
Using one inch wrench, loosen both fitting on each side of pump.
-
Using a crosshead screwdriver, remove the four screws securing the bottom of pump.
-
Disconnect the wires in the rear of pump and pull assembly from fryer.
-
Pull fittings from faulty pump and attach the fittings to new pump, in the same orientation.
-
Install new pump assembly in fryer, in reverse order and then reconnect power to fryer.
Related Content
Replacing the Drain Valve Actuator
Replacing the Filter Motor Relay
Replacing the Gas Control Valves
Replacing the Filter and JIB Lights
Replacing the Filter Pan Switch
LVG 10X Troubleshooting the E-18 Level Probe Error Code
Troubleshooting the E-60 AIF Communication Failure
LVG 10X Troubleshooting the Oil Not Pumping Error Code