Applies to:
Replacing the Check Valve
A check valve is installed in the fill line to each vat to keep oil from flowing out of the vat.
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Disassemble fittings as necessary, remove old valve.
-
Apply Loctite Primer (Henny Penny part no. MS01-572) to internal threads of both the inlet and outlet of new valve.
-
Reassemble fittings to check valve and install valve. Be sure to allow a 1/4 inch gap between check valve and elbow.
Related Content
Replacing the Filter Motor Relay
Replacing the Filter Pan Switch
Replacing the Filter and JIB Lights
Replacing the Oil Level Probes
Adjusting the Drain Valve Actuator
Troubleshooting a Leaking Drain Valve
Troubleshooting an E-82 Error Code
LVE 20X Troubleshooting the Oil Not Pumping Error Code