PFG 600 C7000 Operating Components
This section describes the functions of all operating controls and their components.
Item No. | Description | Function |
---|---|---|
1 |
Decal Switch |
The decal switch is a pressure sensitive membrane switch which activates the functions of the control. |
2 | Menu Board | The menu board displays the products that have been programmed within the control. |
3 | Menu Indicator | The menu indicators, when illuminated, point to the product cycle the control is in. |
4 | Done Indicator | This indicator shows the operator the cooking cycle is completed. |
5 | Digital Display | The digital display is a LED type display which shows the temperature of the oil and the timer countdown of the frying cycle. |
6 |
Ready Light |
The ready light indicates the oil has reached operating temperature and the operator may drop product. |
7 | High Limit Light | This light will illuminate in the event the manual reset high limit has tripped. This indicates the oil temperature has exceeded the safe operating limit. |
8 | Change Switch Indicators | These indicators, when illuminated, show which part of the display is functional for programming such as increasing or decreasing temperature, time, etc. |
9 | Pressure Light | When illuminated, shows the solenoid is closed which allows pressure to build. |
10 | Key Switch | When in the COOK position the unit is in the normal operation mode. In the PROGRAM position the unit is in the program mode. |
11 |
Power Switch |
This switch is a sealed illuminated rocker type switch. When in the COOK position, applies power to the control. When in the PUMP position applies power to the pump motor |
12 | Timer Switch | The timer switch is used to start, stop, or abort a cooking cycle. |
13 | Reset Usage Switch (Program Mode Only) | This switch resets the total number of cycles that have been cooked either in one product or in all products. |
14 | Change Switches (Program Mode Only) | These switches change the value of the displayed number. Such as increasing or decreasing the time of a cook cycle, or increasing or decreasing the temperature of a cook cycle. |
15 | Review Usage Switch (Program Mode Only) | By depressing this switch the display will show you the number of cook cycles that have been cooked for a particular product. |
16 |
Select Function Switch (Program Mode Only) |
This switch will change the function that is being programmed such as time, temperature, alarm, etc. |
17 | Select Product Switch | This switch selects the product you wish to cook or program. |
18 | Select Time Switch | The select time switch selects the interval within a product. There are ten intervals per product. |
19 | Function Display (Program Mode Only) | The function display will show you the function you are in when programming. |
20/27 | Primary and Secondary Contactor | The contactors are relays that route power to the heating elements. The primary relay coil is in series with the high temperature control and the secondary relay coil is in series with the heat control circuit. |
21 |
Thermal Sensor |
The thermal sensor determines the oil temperature. |
22 | High Limit Thermostat | The high limit thermostat is a manual reset control that senses the oil temperature in the event the temperature exceeds the safe operating limit. |
23 | Transformer | The transformer is a step down type transformer. It converts high voltage to lower voltage. |
24/25 | Fuses | The fuses provide an overload protection for the control panel. |
26 | Fan | The fan’s function is to eliminate any heat build up inside the control panel area. |
|
Back-Up High Limit Thermostat (Not Shown) |
This is a back-up high limit thermostat in the event the temperature exceeds the safe operating limit. |
Related Content
PFG 600 Preventative Maintenance Schedule
Temperature Regulation (Single Stage)
Basic Operation for Chick-fil-A
Cleaning the Safety Relief Valve
Operating Controls for Chick-fil-A
PFG-600 Operating the Optional Direct-Connect Oil System
Gas Pilot and Burner Operation
PFG 600 C8000 Control Components
Reference